Am J Alzheimers Dis Other Demen ; 39: 15333175231222695, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38183177

RESUMO

Introduction: To evaluate whether both acute and chronic low-intensity pulsed ultrasound (LIPUS) affect brain functions of healthy male and female mice. Methods: Ultrasound (frequency: 1.5 MHz; pulse: 1.0 kHz; spatial average temporal average (SATA) intensity: 25 mW/cm2; and pulse duty cycle: 20%) was applied at mouse head in acute test for 20 minutes, and in chronic experiment for consecutive 10 days, respectively. Behaviors were then evaluated. Results: Both acute and chronic LIPUS at 25 mW/cm2 exposure did not affect the abilities of movements, mating, social interaction, and anxiety-like behaviors in the male and female mice. However, physical restraint caused struggle-like behaviors and short-time memory deficits in chronic LIPUS groups in the male mice. Conclusion: LIPUS at 25 mW/cm2 itself does not affect brain functions, while physical restraint for LIPUS therapy elicits struggle-like behaviors in the male mice. An unbound helmet targeted with ultrasound intensity at 25-50 mW/cm2 is proposed for clinical brain disease therapy.


Assuntos
Ansiedade , Assistência de Longa Duração , Feminino , Masculino , Animais , Camundongos , Humanos , Ansiedade/terapia , Frequência Cardíaca , Transtornos da Memória , Ondas Ultrassônicas
2.
Front Neurosci ; 17: 1269267, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38053610

RESUMO

Introduction: Low-intensity pulsed ultrasound (LIPUS) is a recognized tool for promoting nerve regeneration and repair; however, the intracellular mechanisms of LIPUS stimulation remain underexplored. Method: The present study delves into the effects of varying LIPUS parameters, namely duty cycle, spatial average-temporal average (SATA) intensity, and ultrasound amplitude, on the therapeutic efficacy using SK-N-SH cells cultured in serum-starved conditions. Four distinct LIPUS settings were employed: (A) 50 mW/cm2, 40%, (B) 25 mW/cm2, 10%, (C) 50 mW/cm2, 20%, and (D) 25 mW/cm2, 10%. Results: Immunochemistry analysis exhibited neurite outgrowth promotion in all LIPUS-treated groups except for Group D. Further, LIPUS treatment was found to successfully promote brain-derived neurotrophic factor (BDNF) expression and enhance the phosphorylation of extracellular signal-regulated kinase (ERK)1/2, protein kinase B (Akt), and mammalian target of rapamycin (mTOR) signaling pathways, as evidenced by western blot analysis. Discussion: The study suggests that the parameter combination of LIPUS determines the therapeutic efficacy of LIPUS. Future investigations should aim to optimize these parameters for different cell types and settings and delve deeper into the cellular response mechanism to LIPUS treatment. Such advancements may aid in tailoring LIPUS treatment strategies to specific therapeutic needs.

3.
Proc Natl Acad Sci U S A ; 120(27): e2218976120, 2023 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-37364092

RESUMO

By 2050, countries around the world are expected to be gradually phasing out fossil fuels and implementing greener energy technologies. In this work, we present a system employing Energy harvesting, a self-powered technology that can recycle energy from the surrounding environment. A high-efficiency radio frequency (RF) energy-harvesting chip was designed and fabricated. With an off-chip antenna and rectifier, the system scavenges ambient RF energy and converts it into usable energy, which is then stored in energy storage elements (such as a supercapacitor or a rechargeable battery). The system can further be implemented as an energy source for charging smart devices. The system-on-chip design consists of a cold start block, a boost converter with maximum power point tracking functionalities, and a charging block. The chip was fabricated using AMS 350 nm technology. Although the system was optimized for harvesting RF energy, it can be easily adapted to harvest other energy sources (i.e., mechanical and thermal energy sources). Using an optimized cold start architecture, the circuit has a cold start voltage of 380 mV. With an improved control strategy of power conversion, the system is capable of continuously charging up to 4.5 V with a broad input voltage range of 100 mV to 10 V and has a peak charging efficiency of 82%.

4.
IEEE Trans Biomed Circuits Syst ; 16(5): 962-971, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35994551

RESUMO

Currently, there is no suitable solution for the point-of-care diagnosis of knee injuries. A potential portable and low-cost technique for accessing and monitoring knee injuries is bioimpedance measurement. This study validated the feasibility of the bipolar electrode configuration for knee bioimpedance measurement with two electrodes placed on a fixed pair of knee acupuncture locations called Xiyan. Then, the study collected 76 valid samples to investigate the relationship between bioimpedance and knee injuries, among whom 39 patients have unilateral knee injuries, and 37 individuals have healthy knees. The self-contrast results indicated that knee injuries caused a reduction of bioimpedance of the knee by about 5% on average, which was detectable at around 100 kHz (p ≈ 0.001). Furthermore, the results analyzed by principal component analysis and support vector machines show that the detection sensitivity can reach 87.18% using the leave-one-out cross-validation. We also proposed a low-cost and portable bioimpedance measurement device that meets the needs for measuring knee joint bioimpedance.


Assuntos
Terapia por Acupuntura , Traumatismos do Joelho , Humanos , Impedância Elétrica , Traumatismos do Joelho/diagnóstico , Eletrodos
5.
Sci Rep ; 12(1): 236, 2022 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-34996955

RESUMO

Electrochemical impedance spectroscopy (EIS) has been used in various applications, such as metal corrosion monitoring. However, many conventional corrosion monitoring setups are bulky and inconvenient for in-situ testing. The purpose of this work is to reduce the size of the whole corrosion monitoring system. We utilized EIS to design a field deployable impedance-based corrosion sensor (FDICS), capable of performing in-situ EIS analysis. Experiments verified the sensor's accuracy, and the results showed that the sensor performed similarly to a bench-top EIS machine when we tested on circuit models. Furthermore, we used the proposed FDICS to monitor a metal corrosion experiment and performed EIS. The result showed that the proposed FDICS is able to obtain the sample's impedance spectroscopy, which could help researchers test its corrosion severity on a metallic sample in-situ. Compared to other bulky conventional setups, our device eliminates the design complexity while still showing insights into the corrosion reaction.